Instrumentation

2-wire level switch

08 July, 2008 | Supplied by: AMS Instrumentation & Calibration Pty Ltd

The NuTec LS2000 level switch from Fluid Components International is designed for 2-wire, 4-20 mA loop power that allows the LS2000 to serve as a drop-in replacement for other 2-wire mechanical float and paddle switches without any wiring modifications during plant retrofit projects, which simplifies installation and reduces cost. The LS2000 is also available for 115/230 VAC or 24 VDC input power and a 6 A relay output.


Coupling pads for ultrasonic flowmeters

08 July, 2008 | Supplied by: AMS Instrumentation & Calibration Pty Ltd

Flexim’s small black pads add to the long-term durability of clamp-on ultrasonic flowmeters.


Series UXF2 ultrasonic flow transmitter

08 July, 2008 | Supplied by: Dwyer Omega (Aust) Pty Ltd

The series UXF2 ultrasonic flow transmitter is an economical alternative to magnetic, vortex and differential pressure transmitters. This transit time flowmeter combines advanced microprocessing detection methods with a versatile design to provide accurate and obstructionless flow measurement of any clean water application.


Festo MS6-SFE flow sensor

08 July, 2008 | Supplied by: Festo Pty Ltd

Capable of operating as a standalone flow sensor, or as part of an MS6 service unit combination, the MS6-SFE features a clearly laid out, backlit LCD showing flow or consumption data combined with a choice of output options.


Multi-gas monitoring system

08 July, 2008 | Supplied by: Thermo Fisher Scientific

Thermo Fisher Scientific has announced the Model 70 FTIR Multi-Gas CEMS, a single analyser, continuous monitoring system capable of measuring up to 10 gases or more for almost any incineration or co-incineration application. The real-time integrated stack gas monitoring system possesses a high level of sensitivity, specificity and dynamic range, with a dynamically aligned interferometer that provides long- and short-term stability.


PrevEx flammability analyser

08 July, 2008 | Supplied by: Lear Siegler Australasia Pty Ltd

The PrevEx flammability analyser provides lower flammable limit monitoring for measuring flammable gases, vapours and mixtures of multiple solvents, in low oxygen, elevated temperature and inert atmospheres.


Acrylic flowmeter

08 July, 2008 | Supplied by: Kobold Instruments Pty Ltd

The KFR acrylic flowmeter offers a balance between low-cost, accuracy and range availability. Bridging the micro-flow and large flow ranges, this meter can provide an effective solution to many industrial applications.


Turbine wheel flowmeter

08 July, 2008 | Supplied by: Kobold Instruments Pty Ltd

The turbine wheel flowmeter type DPE operates according to the well-known blade wheel principle. Numerous liquid media of low viscosity, ranging from distilled water to fuels, alcohol and various chemicals can be monitored with this robust measuring instrument.


SEN pressure sensors

08 July, 2008 | Supplied by: Kobold Instruments Pty Ltd

The SEN pressure sensors are compact and can be used in a variety of applications. The measuring principle uses a thick film ceramic measuring cell, has very good repeatability and is very reliable. Automatic temperature compensation is provided to give great accuracy.


DVZ Series vortex flowmeters

08 July, 2008 | Supplied by: Kobold Instruments Pty Ltd

The DVZ Series flowmeters are compact and inexpensive and can be utilised in all applications for low-viscosity fluids. Since the units operate without any mechanical moving parts, they are practically maintenance free and have distinct advantages compared with units based on the float or rotor principle.


Failsafe manual reset thermostats

01 July, 2008 | Supplied by: Practical Control Solutions

The KMF series of failsafe thermostats monitor temperatures in furnaces, ovens, kilns, boilers or any application where an overtemperature condition would result in a critical failure.


Digital differential pressure gauge

01 July, 2008 | Supplied by: Floyd Instruments Pty Ltd

Crystal Engineering has introduced the XP2i-DP differential digital test gauge which is also capable of data logging. The unit is rugged, intrinsically safe, ATEX certified and has an accuracy of ±0.1% of reading between 20-100% and ±0.02% of full scale between 0-20%.


Vibration level switch

01 July, 2008 | Supplied by: Hawk Measurement Systems Pty Ltd

The level sensing arrangement used in the Gladiator vibration smart switch is suitable for a wide range of liquids and solids, including slurries and pelletised materials.


CUB5 Series panel meter

01 July, 2008 | Supplied by: Control Logic Pty Ltd

Red Lion has announced its CUB5 Series analog panel meters that have a footprint that is 30% smaller than conventional 48 x 96 mm meters.


Self-validating point level sensor

01 July, 2008 | Supplied by: Metaval Engineering Sales

The SafePoint from Monitor Technologies LLC is a self-validating point level sensor for monitoring the presence and absence of powders, granular materials and other bulk solids.