1312/1392 shear-web tension/compression load cells

Wednesday, 01 April, 2009 | Supplied by: Bestech Australia Pty Ltd


The model 1312/1392 shear-web tension/compression load cells from BCM Sensor are alloy steel (1312) and stainless steel (1392) load cells with protection up to an IP66 standard. The 1312 is also nickel plated. They can measure in either tension or compression, and applications for these load cells include hopper scales and vehicles scales.

There are various capacities available, starting from 2 t up to 10 t. The safe overload limit is 150% full-scale output. The accuracy of the shear-web load cell is ±0.03% of the full-scale output, and it has an operating temperature range of -20 to 65 °C. A recommended excitation of 10 VDC/VAC is required, but up to 18 VDC/VAC can be used. The rated output is 2.0±0.01 mV/V.

Online: www.bestech.com.au
Phone: 03 9540 5100