Souping up savings

Wednesday, 14 July, 2021 | Supplied by: Hydro Innovations

Souping up savings

A soup production facility was looking to replace its unreliable surface aerators to save maintenance costs and improve efficiency at its facility. The facility environmental engineer installed the Hydro Innovations Venturi-Aeration solution, which has resulted in improved efficiency and cost savings.

The facility’s previous aerators had been in operation for several years and were not achieving the desired conditioning objectives. Furthermore, whenever one of the submersible pumps plugged or failed, the company had to rent a crane to remove the pump for repairs and then had to use the crane for removal and repair, and to reinstall the repaired pump at additional costs on each occurrence.

As one or more of the submerged pumps was failing at least once if not twice a year, the company began to look for a more viable aeration, mixing and equalisation solution to keep them in compliance.

The facility environmental engineer decided to replace the existing aerators with a Venturi-Aeration Model VA-1400 aerator and a T8 Gorman-Rupp pump.

The Venturi Aeration line of wastewater treatment products was introduced into Australia after its successful application by food processors in the US and Europe. The aerators are used in conjunction with Gorman-Rupp pumps and can be mounted on the banks of basins and lagoons instead of being installed within them.

The former system added dissolved oxygen to mix and equalise the contents in the equalisation tank using submerged aerators. The addition of the dissolved oxygen would cause fats, oils and grease to float so they would not be discharged with the plant’s effluent into the publicly owned treatment works. The submerged aerators were also supposed to provide cooling of the influent process washdown water (at around 40°C).

Since the Venturi aerator is designed to handle 82 L/s, the contents of the equalisation tank can now be recirculated four times over a 24-hour period, achieving greater oxygen transfer and better mixing and equalisation.

The soup production facility is happy with its results since changing over to the Venturi Aerator. The installation is reported to have resulted in annual operating cost savings of more than $112,000.

According to the company, the system has improved the overall equalisation tank performance to produce clearer effluent, while controlling odours, settling solids, cooling the water and hydrolysing fats, oils and greases — causing them to float for better removal efficiency.

With better circulation and cooling in the EQ tank the fats, oils and grease are floated for separation and treatment and are not being discharged with the effluent to the local treatment works, reducing surcharges.

The plant was able to achieve a $6000 annual energy cost reduction, an $89,000 annual reduction in chemical costs, a $12,000 annual reduction in non-compliance charges and further maintenance cost reductions.

The facility environmental manager now has a system that allows him to achieve his discharge permit parameters and he has less concern over maintenance issues and costs.

Originally published here.

Online: www.hydroinnovations.com.au
Phone: 02 9898 1800
Related Products

Phoenix Contact Trio Power power supply

The third-generation Phoenix Contact Trio Power power supply is now available with a protective...

Phoenix Contact PTCB 48 VDC circuit breakers

The PTCB single-channel circuit breakers can now protect loads with a supply voltage of 48 VDC.

NORD Drivesystems single-phase IE2 motors

The more efficient single-phase asynchronous motor now corresponds to efficiency class IE2.


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd