Instrumentation

Mettler Toledo InPro 4850i inline pH electrode

21 December, 2011 | Supplied by: Mettler-Toledo Ltd

The InPro 4850i inline pH electrode is designed specifically for the requirements of the chloralkali industry. The electrode incorporates a sodium-sensitive glass membrane that uses the brine present in chlorine production as a reference. This reference system is hermetically sealed, providing a barrier against oxidising agents.


Emerson Process Management Rosemount 708 Wireless Acoustic Transmitter

05 December, 2011 | Supplied by: Emerson Automation Solutions

Leaking steam traps cause energy and financial losses, and studies estimate that 15-30% of unmaintained steam traps will fail within a 3- to 5-year period. This can equate to a loss of millions of dollars in energy costs.


Dwyer Instruments Series TDFS thermal flow switch

02 December, 2011 | Supplied by: Dwyer Instruments (Aust) Pty Ltd

The Series TDFS thermal flow switch indicates whether the flow rate is above or below a user set flow rate with NO and NC NPN outputs.


Trimec MP series rotary piston flowmeters

01 December, 2011 | Supplied by: AMS Instrumentation & Calibration Pty Ltd

Rotary piston technology has long been established as a simple but reliable metering principle providing high levels of accuracy and repeatability for a wide range of liquids - from extremely viscous lubricants, chemicals and food bases to non-conductive solvents and fuels. Applications include alcohols, acetic acid, caustic soda, ethanol, fuels, grease, glucose, ink, insecticides, latex emulsions, liquid sugar, margarine, mayonnaise, molasses, resin, tallow, urethane, water, xylene and liquid yeast.


Polarographic oxygen measurement

26 November, 2011 | Supplied by: Mettler-Toledo Ltd

For the measurement of oxygen in continuous process analysis, several technologies are available. Because they differ widely in terms of application coverage, field performance and ease of use, the right technology has to be carefully chosen.


Keller Series 35X HTC high-temperature pressure transmitter

21 November, 2011 | Supplied by: Bestech Australia Pty Ltd

The Series 35X HTC high-temperature pressure transmitter from Keller is primarily designed for biotechnology and food industry applications. The pressure of hot media applied to the diaphragm is transferred via an exposed oil-filled spiral capillary to the sensing element. Heat to a maximum of 300°C is therefore safely dissipated to the atmosphere before it reaches the sensing element when the sensor is optimally mounted.


Finetek SE250 rotary paddle level switch

21 November, 2011 | Supplied by: Process Control Services Pty Ltd

The Finetek SE250 rotary paddle level switch is a low-cost rotating paddle switch for level measurement of solids, grains or powders. The spring-loaded folding paddle allows quick and simple installation and removal of the unit from outside of the vessel, simplifying installation and maintenance.


Inline oxygen sensor wins award

21 November, 2011 | Supplied by: Mettler-Toledo Ltd

Mettler Toledo has won the Gold Award for the InPro 6850i G inline oxygen sensor in the Gas Analysis category at the 2011 Golden Gas Awards.


Weber vent-captor 3202.30 airflow meter

16 November, 2011 | Supplied by: Automated Control Pty Ltd

The Weber vent-captor 3202.30 airflow meter is small, self-contained and epoxy resin-encapsulated. It is claimed to operate with high accuracy and repeatability even under changing working conditions.


Honeywell 854 Servo level gauge with enhanced overfill detection

08 November, 2011 | Supplied by: Honeywell Process Solutions

Honeywell has announced key enhancements to its 854 Servo level gauge, which is now equipped with a Servo Auto Test feature. This solution has been approved for Safety Integrity Level-2 and 3 (SIL-2/SIL 3) applications and increases the gauge’s diagnostic coverage.


Mettler Toledo ISM technology

07 November, 2011 | Supplied by: Mettler-Toledo Ltd

ISM (Intelligent Sensor Management) technology from Mettler Toledo is designed to allow users of process analytical equipment to reduce the maintenance costs of loops, while increasing the safety of the production process. Sensors equipped with ISM are continuously monitored for defects and wear to anticipate failure before it happens.


Mettler Toledo M800 multichannel, multiparameter transmitter

04 November, 2011 | Supplied by: Mettler-Toledo Ltd

The Mettler Toledo M800 is a multichannel, multiparameter analytical transmitter line. The series operates with Intelligent Sensor Management (ISM) sensors for pH/ORP, conductivity/resistivity, oxygen (dissolved as well as gas) and ozone. Up to four channels are available for measurement of any combination of the above parameters, plus inputs for flow.


Vega WeighTrac radiation-based belt weigher

03 November, 2011 | Supplied by: VEGA Australia Pty Ltd

WeighTrac is a radiation-based sensor for precise determination of the feed rate of bulk solids. It measures contactlessly with the help of gamma radiation and is suitable for mass flow measurement on conveyers. Its frame construction allows simple installation and retrofit.


Emerson Process Management FloBoss S600+ panel-mounted fiscal flow computer

30 October, 2011 | Supplied by: http://www2.emersonprocess.com/en-US/brands/remote/liquids_flow_computers/S600/Pages/S600.aspx

The FloBoss S600+ is a panel-mounted fiscal flow computer designed specifically for hydrocarbon liquid and gas measurement where versatility and accuracy are high priorities. It allows multistream, multistation applications to be configured for simultaneous metering of gas, wet gas, crude oil, refined products, LPG and NGL.


Katronic KATflow clamp-on ultrasonic flowmeters

20 October, 2011 | Supplied by: AMS Instrumentation & Calibration Pty Ltd

The Katronic KATflow clamp-on ultrasonic flowmeters work on the transit-time method. This is based on the principle that sound waves travelling with the flow will move faster than those travelling against it. The resulting difference in transit time is directly proportional to the flow velocity of the liquid and consequently to the volumetric flow rate.


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd